High quality of the product has been verified by a test at the INTERTEK laboratory in New York (USA) and confirmed by a certificate.
This type of data communications cables are intended for indoor horizontal and vertical installations in data communications networks. All ALANTEC cables are compliant with the CPR directive on the classification of construction products in terms of their resistance to fire and defining test methods for cables intended for installation in buildings.
The product is covered by a 25-year system warranty.
Technical Specifications
CONSTRUCTION AND ELECTRICAL PARAMETERS
Category 6
Class E (250MHz standard) with extended characteristics up to 475 MHz / 1 Gb/s
AWG 4x2x23AWG cross section
Conductors single stranded copper, diameter 0.57 mm (23AWG)
Insulation polyethylene
CPR fire classification (Euroclass) B2ca
Fire load (MJ/m) 0.60 (approx.)
Centre 4 pairs twisted on a cross-shaped core insert
Shield none
Coating halogen-free flame retardant, low smoke and corrosive gas emission material (LSOH/FRNC)
PoE 802.3 at
Color violet
ELECTRICAL PROPERTIES AT 20ºC
DC resistance ≤ 93.8 Ω /km
Variable resistance ≤ 2%.
Insulation resistance (500V) ≥ 5000 MΩ *km
Capacitive reactive resistance at 800 Hz nom. 48 nF/km
Variable reactive capacitive resistance ≤ 1500 pF/km
Characteristic apparent resistance (1-1000MHz) (100 ± 15) Ω
Nominal propagation speed (NVP) 69%
Delayed propagation Nominally ≤ 535 ns/100m
Delay angle Nominally ≤ 20 ns/100m
DC system tester, 1 min. (core) 1000 V
MECHANICAL PROPERTIES
Bending radius 4 x outer diameter
Max. drawing force 80 N
Temperature range during use -30°C to +75°C
Temperature range during installation 0°C to +50°C
Outer diameter 5,9 mm
Weight kg/km 59
Packing spool (500m)